Competitive Mixed refrigerant R404A prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please call us at +8618136850665 or mail to
sales6@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: sales6@liwei-chem.com
As a leading Mixed refrigerant R404A supplier, we deliver high-quality products across diverse grades to meet evolving needs, empowering global customers with safe, efficient, and compliant chemical solutions.
What are the ingredients of Mixed refrigerant R404A?
Mixed refrigerant R404A is composed of several refrigerants mixed together. Its components mainly contain R125, R143a and R134a. These three are combined according to a specific ratio to form R404A.
Among them, R125 accounts for about 44%. It can increase the cooling effect in the refrigeration system and has a certain adjustment effect on the system pressure. R143a accounts for about 52%. This component is crucial to improve the cooling efficiency and can make the system more effectively convert heat. And R134a accounts for about 4%. Although the proportion is relatively small, it also plays an important role in stabilizing the system performance and reducing energy consumption.
R404A has many characteristics and its cooling capacity is quite strong. It is suitable for a variety of refrigeration equipment, such as commercial refrigeration and refrigeration systems. And its thermal properties are suitable, which can make the system run efficiently. Because of the synergistic effect of mixed components, it can maintain good refrigeration performance under different working conditions, and is widely used in today's refrigeration field.
What is the applicable temperature range of Mixed refrigerant R404A?
The mixed refrigerant R404A is suitable for medium and low temperature refrigeration systems, and its applicable temperature range is very critical. The temperature suitable for this refrigerant is between -40 ° C and -5 ° C. In this temperature range, R404A can show good refrigeration performance, providing stable and efficient refrigeration for various types of refrigeration equipment.
In lower temperature scenarios, such as freezers, R404A can effectively maintain a low temperature environment and ensure that items are properly preserved. It evaporates and absorbs heat in the evaporator, thereby achieving the purpose of refrigeration. And in relatively high temperature refrigeration conditions, such as some refrigeration equipment, R404A can also rely on its characteristics to stably meet the refrigeration requirements and ensure the normal operation of the equipment.
However, it should be noted that if the temperature exceeds this range, whether it is too high or too low, it may affect the performance of R404A. If the temperature is too high, its cooling capacity may decrease, resulting in poor cooling effect; if the temperature is too low, it may cause abnormal system pressure and other conditions, causing damage to the equipment. Therefore, when using R404A, it is necessary to ensure that the operating temperature of the refrigeration system is within a suitable range, so as to give full play to its advantages and maintain the stable and efficient operation of the refrigeration equipment.
What are the performance characteristics of Mixed refrigerant R404A
The mixed refrigerant R404A is made of a variety of refrigerants mixed in a specific ratio. It has a number of characteristics, which are quite descriptive.
First, the refrigeration efficiency is quite high. Among many refrigeration systems, R404A exhibits good refrigeration performance, can quickly cool down, make the environment reach the required low temperature state, and can provide reliable refrigeration support for refrigeration, freezing and other fields.
Second, good thermal performance. Its evaporation and condensation characteristics are suitable for the operation requirements of most refrigeration equipment, and can maintain a stable thermal cycle under different working conditions to ensure efficient operation of the system and reduce energy consumption.
Third, excellent chemical stability. Under normal use conditions, R404A is not easy to chemically react with other substances in the system, which can effectively protect the components of refrigeration equipment, prolong the service life of the equipment, and reduce maintenance costs.
Fourth, it has good miscibility with lubricating oil. It can be well mixed with common refrigeration system lubricating oils to ensure the lubrication effect of key components such as compressors, so that the equipment can operate smoothly and reduce the probability of mechanical wear and failure.
However, it should also be noted that the greenhouse effect potential value of R404A is relatively high, which has an impact on the environment. Therefore, during use, when following relevant environmental protection regulations, pay attention to the rational use and recycling of refrigerants to reduce their negative effects on the environment.
What are the advantages of Mixed refrigerant R404A compared to other refrigerants?
The mixed refrigerant R404A has its own unique advantages compared with other refrigerants. It is quite outstanding at the end of refrigeration efficiency. R404A has good heat transfer, can refrigerate quickly, make the refrigeration system run efficiently, cool down quickly and stably, and can cause the cold environment temperature to meet strict standards.
Furthermore, the pressure characteristics of R404A are also excellent. Under normal working conditions, its evaporation pressure and condensation pressure are well adapted, so that the refrigeration system can operate stably and avoid failures. And this refrigerant has good chemical stability, is not easy to react chemically in the refrigeration system, can keep the system components intact for a long time, prolong its service life, and saves the trouble of frequent repairs.
In addition, R404A has good oil solubility. It can well dissolve with the lubricating oil commonly used in the refrigeration system, and does not cause oil blockage and other obstacles to refrigeration, ensuring the smooth and unobstructed refrigeration cycle and maintaining the high efficiency of the system.
And the environmental performance of R404A is also commendable. Although it is not completely free of greenhouse effect, its greenhouse gas emissions have been greatly reduced compared with some refrigerants in the past, and it has made a great contribution to environmental protection. It meets the requirements of environmental protection in the times and can be used in many refrigeration scenarios that require environmental protection.
Mixed refrigerant R404A What are the precautions during use
For mixed refrigerant R404A, there are many things to pay attention to when using it. First and foremost, the regulation of temperature and pressure must be accurate. This refrigerant is suitable for a specific temperature range. If it exceeds this range, the refrigeration efficiency may be damaged, and the equipment may fail. Therefore, when using it, closely monitor the system temperature and pressure, and adjust it according to its changes to ensure its stable operation.
Furthermore, R404A has certain toxicity and flammability. Although the toxicity is weak, it can also endanger people in closed spaces or when a large number of leaks. And it is flammable, and there is a risk of explosion in case of open flames and hot topics. Therefore, when the place of use is well ventilated and fireworks are strictly prohibited, firefighting equipment and leakage emergency treatment equipment should also be prepared to prevent accidents.
Equipment adaptation is also key. R404A has specific requirements for the material of refrigeration system components, and some materials come into contact with it or react chemically, which will damage the life of the equipment. Therefore, when selecting equipment, it is necessary to ensure that it is suitable for R404A, and the installation and maintenance are operated according to specifications. Check the equipment regularly to detect and repair potential problems in time.
In addition, the charging amount also needs to be precisely controlled. Too much or too little charging affects the cooling effect. If the system pressure is too high, the compressor load is increased, and the energy consumption is greatly increased; if the charging is too low, the cooling capacity is insufficient. Therefore, the filling amount should be accurately measured according to the equipment specifications and operation guidelines.
In short, with the mixed refrigerant R404A, care should be taken in terms of temperature and pressure, safety protection, equipment adaptation, and charging amount to ensure the safe and efficient operation of the refrigeration system.