Mixed Refrigerant R406a
Refrigerant Series Fluorine Material Series Rubber Series Fluorine Refrigerant Other Products

Mixed refrigerant R406A

Shijie Chemical

    Specifications

    HS Code

    525022

    Chemical Composition HCFC-22 (55%), HCFC-142b (41%), isobutane (4%)
    Odp 0.034
    Gwp 2180
    Boiling Point -40.2°C at 1 atm
    Critical Temperature 106.7°C
    Critical Pressure 4.97 MPa
    Flammability Class 2L (mildly flammable)
    Vapor Density 3.96 kg/m³ at 21.1°C
    Liquid Density 1.186 g/cm³ at 25°C
    Specific Heat Capacity Liquid 1.13 kJ/(kg·K) at 25°C
    Specific Heat Capacity Gas 0.69 kJ/(kg·K) at 25°C

    As an accredited Mixed refrigerant R406A factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Mixed refrigerant R406A packaged in 10 - kg cylinders for easy handling.
    Storage Mixed refrigerant R406A should be stored in a well - ventilated, cool area. Keep it away from heat sources, flames, and direct sunlight to prevent pressure build - up. Store containers upright and ensure they are tightly sealed to avoid leakage. Adhere to local safety regulations and maintain a storage environment with temperatures typically below 50°C.
    Shipping Mixed refrigerant R406A is shipped in specialized containers designed to handle refrigerants. It must comply with strict safety regulations during transportation to prevent leaks and ensure safe delivery.
    Free Quote

    Competitive Mixed refrigerant R406A prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please call us at +8618136850665 or mail to sales6@liwei-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: sales6@liwei-chem.com

    Mixed refrigerant R406A
    General Information
    Historical Development
    "The Evolution of Mixed refrigerant R406A"
    Mixed refrigerant R406A is also a refrigerant working fluid and the like. At the beginning, various craftsmen studied the formula to meet the needs of refrigeration. At first, the performance was not good, the refrigeration efficiency was weak and the stability was lacking.
    Then, the workers worked tirelessly to improve the formula and tried to mix chemicals in different proportions. After years of research, the performance has gradually improved, and the refrigeration is efficient and stable. It is also widely used in refrigeration equipment, refrigerators, freezers and the like.
    Over the years, the technology is changing with each passing day. Although R406A has its merits, there is a call for environmental protection. Because it contains chlorofluorocarbons, it damages the atmospheric ozone layer. Therefore, the study of new quality generation R406A is aimed at protecting the environment and maintaining the balance of the earth's ecology.
    Product Overview
    "Product Overview of R406A"
    R406A is also a mixed refrigerant. Its properties and qualities are long, and it is made up of a variety of refrigerants in exquisite proportions. This product is widely used and is commonly found in refrigeration appliances, such as household refrigerators, small freezers, etc. It can efficiently achieve the effect of refrigeration and maintain a low temperature environment in the box.
    Its characteristics are remarkable, it has good heat transfer, fast cooling speed, and can quickly cool down. And the chemical properties are stable, safe and reliable, and it is safe under general working conditions. It should also be used with attention, and it must be operated in accordance with specifications to ensure long-term stability. Adhering to scientific use can add luster to the refrigeration field, and those who use it can benefit from cooling and convenience.
    Physical & Chemical Properties
    "On Physicalization"
    Mixed refrigerant R406A has unique physical and chemical properties. Its boiling point is suitable, and it evaporates and condenses smoothly in the refrigeration system. This agent has good thermal conductivity and can efficiently transfer heat, making the refrigeration effect remarkable. And it has good chemical stability, is not easy to react with other substances in the system, and can ensure long-term stable operation of the equipment. Its ingredients are exquisite and have multiple advantages. It is widely used in the refrigeration field. As a key material for efficient cooling and temperature control, it helps all kinds of refrigeration equipment to play an excellent performance with its unique physical and chemical characteristics.
    Technical Specifications & Labeling
    Technical Specifications and Identification of Mixed Refrigerant R406A (Commodity Parameters)
    The mixed refrigerant R406A is a commonly used product in the refrigeration field. Its technical specifications are related to refrigeration efficiency and safety. The composition of the agent is accurately proportioned, with specific parameters such as boiling point and freezing point.
    As far as the identification is concerned, its commodity parameters need to be clearly stated. On the packaging, when the proportion of ingredients, the scope of application, and precautions are clearly defined. If what kind of refrigeration equipment is suitable, the protective requirements during operation. Clear identification can ensure that the user has no risk of misuse, and also enable all parties to act in accordance with the specifications when the product is circulated in the market, so as to achieve the purpose of safe and efficient use and ensure the smooth operation of the refrigeration industry.
    Preparation Method
    "Method of Preparation of Mixed Refrigerant R406A"
    To make Mixed refrigerant R406A, its raw materials and production process are the key. The raw materials need to be selected from high-quality products to ensure the purity of the product. In the production process, the reaction steps should be gradual.
    At the beginning, prepare all the raw materials in precise proportions to make them fit each other. Then, put them into special utensils, control the temperature appropriately, and make them fully react. When reacting, observe its changes and adjust them in a timely manner.
    As for the catalytic mechanism, choose a high-efficiency catalyst to accelerate the reaction and improve its yield. And set strict quality inspection. After each step, carefully check the product, if it does not meet the standard, remake it. In this way, the Mixed refrigerant R406A product can be prepared.
    Chemical Reactions & Modifications
    On the chemical reaction and modification of Mixed refrigerant R406A
    Mixed refrigerant R406A is a commonly used substance in refrigeration. Its chemical reaction is related to refrigeration efficiency and environmental impact. In the refrigeration system, R406A interacts with various components, or corrodes, damaging the system. Therefore, it is crucial to understand its reaction mechanism.
    The modification method aims to optimize its performance. It can be used to add additives to adjust its physical and chemical properties, increase stability and reduce corrosion. Or change the formula ratio to achieve better refrigeration effect. This move not only ensures the efficiency of refrigeration, but also reduces environmental pollution, which is in line with the needs of current environmental protection.
    Chemical response and modification are key to the application of R406A. Good research and use can make this product more effective and achieve long-term development in the field of refrigeration.
    Synonyms & Product Names

    Mixed refrigerant R406A is a mixed refrigerant used in refrigeration. Its synonymous names are many, such as R-406A, and it is also called a specific mixed refrigerant substance. As for the trade name, it is often found in the logo of the refrigeration industry, such as "Cool 406A Refrigerant". This R406A, with its unique chemical ratio, is used in various refrigeration appliances and can efficiently achieve the effect of refrigeration. Its synonymous name and trade name are common in the industry, which is convenient for all parties to identify and communicate. It is indispensable in the refrigeration industry.
    Safety & Operational Standards
    "Mixed refrigerant R406A Product Safety and Operation Specifications"
    Mixed refrigerant R406A is a mixed refrigerant commonly used in the refrigeration field. It is related to the stable operation of the equipment, the standard of operation and use, and cannot be ignored.
    In terms of safety, this agent has certain flammability, so the storage place must be kept away from open flames and hot topics. The warehouse should be well ventilated and have moderate temperature and humidity to avoid safety risks due to environmental discomfort. When handling, handle it with care to prevent damage and leakage of the container. If it leaks accidentally, leave the scene quickly, do not ignite, start the ventilation device quickly, and deal with it according to emergency methods.
    As for the operating specifications, before use, it is necessary to read the equipment user manual carefully and be familiar with the system's adaptation requirements for R406A. When filling, follow the precise quantity and regulations to prevent excessive or improper charging damage to the equipment. The operating environment should be clean and free of impurities from entering the system to cause failure.
    Daily maintenance, often check the equipment seal, check the pressure, temperature and other parameters. If there is any abnormality, immediately stop the machine for investigation. During maintenance, professionals operate according to the regulations, first drain the refrigerant, do a good job of protection, and then repair.
    In this way, strict adherence to safety and operating standards can enable Mixed refrigerant R406A to operate safely and efficiently in the refrigeration industry, avoid accidents, and ensure the safety of equipment and people.
    Application Area
    Mixed refrigerant R406A has a wide range of applications. In the refrigeration industry, it can be used as a refrigerant for refrigerators, freezers, etc., so that the contents can be kept cold and not rotten. And in the genus of air conditioners, it can adjust the indoor temperature, making it suitable for human habitation. And in the industrial refrigeration process, it also has its place of use, helping to control the temperature accurately and ensure the stability of production. Its suitability can meet the needs of various refrigeration, and it has extraordinary effects in the fields of cold preservation, temperature regulation and temperature control. It is an indispensable material for the refrigeration industry.
    Research & Development
    "Research on Mixed Refrigerant R406A"
    In recent times, cold things have become more and more exquisite. Mixed refrigerant R406A is a new research product in the cold field. Its properties are both high-quality refrigerants, with good energy efficiency and certain environmental friendliness.
    Research and research, research and research, study its physical properties, analyze its formation, and use the same formula, and then research again and again, and get this good result.
    Its use in the field of business and people's livelihood, its use, or cold refrigeration, or air quality, all have excellent performance. Not yet, I hope it can not be refined, and on the road of cold, it will be better again, and benefit the world.
    Toxicity Research
    "On Poisons"
    In modern times, there is a thing called Mixed refrigerant R406A, which is widely used in work. However, the nature of the poison cannot be ignored.
    Examine, the toxicity of this thing is related to life. Or enter the body, it can cause discomfort lightly, such as dizziness in the head and poor breathing; it can damage the viscera and endanger life. The signs of the poison, your mileage may vary, or speed or slow.
    Today's study of its toxicity is to prevent it before it happens. Make users aware of its risks and follow the rules to avoid harm. In the workplace, make good protective equipment to make poisonous gas difficult to invade. Doctors should also understand its toxicology, and in case of poisoning, they can quickly apply rescue and treatment methods. In this way, the harm can be reduced and the well-being of the public can be ensured.
    Future Prospects
    "Future Prospects"
    There are currently mixed and cooled R406A products, and their future development is not yet available. This high-performance cooling system can be effective in multiple domains. In the field of refrigeration and refrigeration, the ingredients can be guaranteed to be as beautiful as ever; in the air field, it can be used in a pleasant and pleasant environment.
    And with the development of science and technology, its efficiency may be better, and the researchers will not change the formula to make it more reliable and efficient. In the future, R406A cooling system will definitely be able to be used in important places in the market, and the development of various industries will be added, which will greatly enhance the color of the cold industry.
    Where to Buy Mixed refrigerant R406A in China?
    As a trusted Mixed refrigerant R406A manufacturer, we deliver: Factory-Direct Value: Competitive pricing with no middleman markups, tailored for bulk orders and project-scale requirements. Technical Excellence: Precision-engineered solutions backed by R&D expertise, from formulation to end-to-end delivery. Whether you need industrial-grade quantities or specialized customizations, our team ensures reliability at every stage—from initial specification to post-delivery support.
    Frequently Asked Questions

    As a leading Mixed refrigerant R406A supplier, we deliver high-quality products across diverse grades to meet evolving needs, empowering global customers with safe, efficient, and compliant chemical solutions.

    What are the ingredients of Mixed refrigerant R406A?
    Mixed refrigerant R406A is composed of a combination of various refrigerants. Among them, the main ingredients contain R22, R142b and R600a. R22, whose chemical name is dichloromethane, has a long-standing reputation in the field of refrigeration and has good refrigeration performance. However, it is gradually controlled because of its damage to the ozone layer. R142b, that is, chlorodifluoroethane, has stable chemical properties and a large latent heat of evaporation, which can help optimize refrigeration efficiency in mixed refrigerants. R600a is isobutane, a natural refrigerant, which is environmentally friendly, has almost no greenhouse gas emissions, and has good cooling effect. These three ingredients are mixed in a specific ratio, giving R406A a variety of advantages. Its cooling capacity is considerable, it can operate stably under different working conditions, and is suitable for many refrigeration equipment, such as household refrigerators, freezers, etc. And because of the environmental protection characteristics of some components, it has a slightly smaller impact on the environment than traditional refrigerants. In the development process of the refrigeration industry, it is an important transitional mixed refrigerant, which strikes a balance between ensuring refrigeration demand and environmental protection.
    What is the scope of application of Mixed refrigerant R406A?
    Mixed refrigerant R406A is a mixture of various refrigerants, and its application range is quite wide. In the field of refrigeration, it is commonly found in household and commercial refrigerators, freezers, etc., which can help it achieve good refrigeration effect and preserve food, goods, etc. This refrigerant is also used in air conditioning systems. Some small split air conditioners may be used. With its characteristics, the indoor temperature can be lowered to create a comfortable environment.
    In small refrigeration equipment, such as car refrigerators, R406A can also play a role in meeting the needs of food refrigeration during the journey. Its advantage is that the refrigeration performance is relatively stable, and it can adapt to different working conditions to a certain extent. However, it also has limitations. Some large refrigeration systems may be difficult to fit due to high requirements for refrigeration capacity and energy efficiency. And in terms of environmental protection, although some traditional refrigerants have made progress, there is still a gap compared with emerging green and environmentally friendly refrigerants. In short, R406A has suitable application scenarios in the field of common small and some medium-sized refrigeration equipment, which can meet many refrigeration needs.
    Mixed refrigerant R406A compared to other refrigerants
    The mixed refrigerant R406A does have its own specific advantages over other refrigerants.
    First, the temperature slip of R406A is relatively small. This makes the temperature change more stable during the operation of the refrigeration system, and the temperature fluctuation of the cooled goods can be maintained slightly. Like a boat on a river, the water waves are gentle, the boat is stable, and the goods will not be damaged due to large shaking. In the refrigeration scene, this feature allows the quality of the refrigerated goods to be more stable, and will not affect its character, taste or quality due to large fluctuations in temperature.
    Second, it has good heat transfer performance. Just like an unimpeded passage, heat transfer is fast and efficient. When the refrigeration equipment is in operation, it can quickly export heat, make the refrigeration space quickly cool down, and achieve the required low temperature environment. In this way, the refrigeration efficiency can be improved, and the energy consumption can also be reduced, which is a double benefit.
    Third, the compatibility of R406A is quite good. It can coexist harmoniously with many commonly used refrigeration system materials, such as compressor lubricants, sealing materials, etc., without conflict. Like good ministers and good generals, they cooperate with each other in the court to help the cause. This compatibility makes the design and maintenance of the refrigeration system more convenient, without the need to worry about the conflict between refrigerants and materials, and can also prolong the service life of the system and reduce maintenance costs.
    Fourth, the refrigerant is also commendable in terms of safety. Its chemical properties are relatively stable, non-flammable, and non-explosive. During use, it can provide a more reliable safety guarantee for the operator and the surrounding environment, just like a strong barrier, protecting the safety of one party.
    Mixed refrigerant R406A What are the precautions during use
    Mixed refrigerant R406A is a mixture of various chemical substances. When using it, many matters must be paid attention to. The first one is safety. This refrigerant contains flammable components, so when using it, it is necessary to keep away from fire sources such as open flames and static electricity to prevent the risk of fire and explosion. The operating site should ensure good ventilation so that the leaking gas can be discharged in time to reduce the possibility of combustible gas accumulation.
    Furthermore, it is related to its physical characteristics. The pressure-temperature relationship of R406A is different from that of other refrigerants. When charging, recovering and system debugging, it needs to be operated accurately according to its characteristics. The charging amount also needs to be precisely controlled. Too much or too little will affect the efficiency of the refrigeration system, resulting in poor cooling effect and increased energy consumption.
    Equipment matching is also key. The compressor, condenser, evaporator and other components used must be adapted to the characteristics of R406A. If the equipment is not selected properly, it will be difficult to achieve the ideal cooling effect, or even damage the equipment. And the sealing of the system is crucial, because leakage not only causes the cooling capacity to decrease, but also pollutes the environment and increases safety hazards, so it is necessary to check the sealing status regularly.
    Personnel operation skills and knowledge are also indispensable. Those who operate this refrigerant should be professionally trained and familiar with its characteristics, operating procedures and emergency response methods. In the event of an emergency such as a leak, it can be responded to quickly and properly to reduce the harm.
    Recycling and disposal should not be underestimated. Discarded R406A should not be discharged at will, and should be recycled in accordance with relevant regulations to prevent damage to the atmospheric environment. In this way, the mixed refrigerant R406A can be used safely and efficiently.
    What are the storage conditions of Mixed refrigerant R406A?
    The mixed refrigerant R406A is a refrigerant composed of a variety of chemical substances. Its storage conditions are very important, which is related to the maintenance of safety and performance.
    The first to bear the brunt is the temperature. It should be stored in a cool place to avoid high temperature. If it is in a high temperature environment, the internal pressure of the refrigerant or the sudden rise will cause the risk of rupture of the container. If it is placed in the open air under the hot summer sun, it should not be placed in the open air. It should be placed in a shaded and ventilated place to prevent the temperature from exceeding 30 ° C.
    The second time is humidity. It should be avoided in a humid place to cover moisture or chemically react with some components in the refrigerant, which will damage its refrigeration performance. Therefore, it should be stored in a dry place and in a warehouse. If conditions permit, dehumidification equipment can be set up to keep the relative humidity between 40% and 60%.
    Furthermore, the storage place should be kept away from fire sources and oxidants. R406A is flammable, and it is easy to burn and explode in case of open flames and hot topics. Oxidants can also react violently with it, causing danger. There should be no fireworks around, and it should be placed separately from the oxidant to keep a safe distance.
    Repeat, the storage container must be intact and tightly sealed. If the container is damaged, refrigerant or leakage, it will waste resources, pollute the environment, and damage the refrigeration system. After each use, make sure to seal the container tightly to prevent air and moisture from invading. At the end of
    , the storage area should be clearly marked. Indicate "Mixed refrigerant R406A, flammable, special storage required" and other words, so that the staff can understand, operate cautiously, and follow safety procedures. In this way, the safety and stability of R406A storage can be guaranteed for use.