As a leading R407C Refrigerant supplier, we deliver high-quality products across diverse grades to meet evolving needs, empowering global customers with safe, efficient, and compliant chemical solutions.
What are the main application fields of R407C refrigerant?
R407C refrigerant is a genus of mixed refrigerants. It is composed of R32, R125 and R134a mixed in a specific ratio. It is widely used and has been exhibited in many fields.
In the field of household air conditioners, R407C refrigerant performs quite well. Household air conditioners need efficient cooling and stable operation. R407C has good heat transfer characteristics and moderate pressure, which can effectively meet this demand. Summer is hot and indoor heat is unbearable. Household air conditioners rely on the operation of R407C refrigerant to quickly cool and create a cool and comfortable environment to protect people from the heat.
In the commercial refrigeration field, R407C is also indispensable. Equipment such as refrigerated display cabinets and cold storage in supermarkets need long-term stable cooling effect to preserve food and other goods. In such scenarios, R407C refrigerant can provide continuous and reliable cooling capacity to ensure that the quality of goods is not damaged.
In industrial refrigeration, R407C refrigerant also has a place. Some industrial production processes require precise temperature control. R407C can meet the requirements of refrigeration accuracy and stability in such industrial scenarios, and help industrial production proceed in an orderly manner.
In addition, in some special refrigeration devices, R407C refrigerant can also play an important role due to its unique physical and chemical properties. In short, R407C refrigerant, with its excellent performance, occupies an important position in many refrigeration-related fields such as household, commercial and industrial, providing key refrigeration support for people's lives and production.
What are the advantages and disadvantages of R407C refrigerant?
R407C refrigerant is a kind of mixed refrigerant, which is composed of R32, R125 and R134a in a specific ratio. Its advantages and disadvantages are mutually apparent, as follows:
Advantages
1. ** Good thermodynamic properties **: R407C has good cooling and heating capacity, suitable evaporation and condensation characteristics, and can show good heat transfer performance in many refrigeration systems, effectively achieving refrigeration or heating purposes. It is widely used in air conditioners, chillers and other equipment.
2. ** Excellent environmental characteristics **: Compared with some traditional refrigerants, such as R22, its ozone layer destruction coefficient is nearly zero, and the greenhouse effect coefficient is relatively low, which is more suitable for environmental protection. It is one of the sustainable development refrigeration solutions.
3. ** Compatibility is acceptable **: It has certain compatibility with system materials, such as compressor lubricants, sealing materials, etc. When upgrading or modifying some existing refrigeration systems, there is no need to change the system materials significantly, which can reduce the cost and difficulty of transformation.
Disadvantages
1. ** Temperature slip phenomenon **: R407C is a non-azeotropic mixed refrigerant, and there is temperature slip during the phase change process. That is, when evaporating or condensing, the temperature will continue to change rather than remain constant. This phenomenon may reduce the heat exchange efficiency of the system, requiring more sophisticated system design and control to achieve optimal performance and increase the complexity of design and debugging.
2. ** Complex leak detection and filling **: Due to temperature slip and specific requirements of component ratio, leak detection and filling operation is more complicated than that of a single refrigerant. If the system leaks, the escape rate of different components may be different, resulting in changes in the remaining refrigerant composition and affecting the refrigeration performance. When refilling, it is necessary to precisely control the proportion of each component, which requires higher requirements for maintenance technicians.
3. ** Relatively high cost **: Production and preparation require precise control of the proportion of each component. The process is complicated, resulting in higher cost than some traditional refrigerants. This may limit its application and promotion to a certain extent, especially for cost-sensitive markets and projects.
What is the filling method of R407C refrigerant?
R407C refrigerant is one of the mixed refrigerants, which is made of R32, R125 and R134a in a specific ratio. The filling method is quite exquisite, and the details are as follows:
First of all, ensure that the refrigeration system has been properly cleaned and there is no risk of leakage. When cleaning the system, use clean tools and appropriate cleaners to carefully remove internal impurities and oil stains, and then blow with nitrogen to ensure that the system is dry and clean. To check for leaks, stress testing or leak detectors can be used. If there is a leak, it must be repaired in time.
Furthermore, the R407C charging amount is accurately determined according to the specifications and design requirements of the refrigeration equipment. Too much or too little charging will affect the cooling effect and equipment performance. This charge amount is often marked on the equipment nameplate or technical documents, and should be strictly followed when operating.
Before filling, the R407C refrigerant cylinder should be properly connected to the refrigeration system. When connecting, ensure that the interface is tight to prevent leakage. And the connection process must be carried out in a well-ventilated place without fire.
Before opening the refrigerant cylinder valve, the refrigeration system should be in a vacuum state. Use a vacuum pump to extract air and non-condensable gas from the system to make the system reach the specified vacuum degree. This can prevent air and moisture from mixing into the system, affecting the cooling effect and equipment life.
Slowly open the cylinder valve to allow the R407C refrigerant to slowly flow into the refrigeration system. During the filling process, pay close attention to the system pressure and temperature changes, and adjust the filling speed according to the actual situation. If the charging speed is too fast, it is easy to cause the system pressure to rise sharply and cause a safety accident.
When the charging is close to the specified amount, the speed should be slowed down and the charging amount should be precisely controlled. You can use the weighing method or the method of measuring the pressure and temperature of the system to determine whether the charging amount is up to standard.
After the filling is completed, close the cylinder valve first, and then disconnect the connecting pipe. After that, check the charging interface again to ensure that there is no leakage.
In short, the R407C refrigerant charging work needs to be rigorous and meticulous, and operate strictly according to the standard process to ensure the normal operation of the refrigeration system and good cooling effect.
What are the characteristics of R407C refrigerant compared to other refrigerants?
R407C refrigerant has unique advantages over other refrigerants in the field of refrigeration. It is a mixed refrigerant, which is composed of R32, R125 and R134a in a specific ratio.
First of all, its thermodynamic properties. The phase change characteristics of R407C are different from that of a single refrigerant. Its phase change temperature slips, making the heat transfer process in the evaporator and condenser non-isothermal. This characteristic, under specific working conditions, can make the system heat transfer better and energy efficiency may be improved. For example, in a refrigeration equipment, the use of R407C refrigerant, the temperature distribution in the evaporator is better, the heat transfer temperature difference between the refrigerant and the cooled material is reduced, thereby reducing irreversible losses and improving refrigeration efficiency.
Times and environmental performance. Compared with previous chlorine-containing refrigerants, R407C does not contain chlorine atoms, so it has no risk of damaging the ozone layer, and its ozone depletion potential (ODP) is zero. And its global warming potential (GWP) is relatively moderate, which is in line with the current environmental protection trend, and is favored by many refrigeration equipment.
Furthermore, its compatibility with system components is also considerable. The pressure and temperature characteristics of R407C are similar to those of R22, which is quite advantageous when many old systems with R22 as refrigerant are retrofitted. In many cases, R407C can be used with only minor adjustments to the system, such as changing lubricants and adapting expansion valves, to reduce the cost of retrofit.
However, R407C is not perfect. Although its heat transfer performance is commendable, in some working conditions, there is still a gap compared to some new single refrigerants. And because it is a mixed refrigerant, if the system leaks, the proportion of component escape may be different, causing the refrigerant composition to change and affecting the refrigeration performance, so the system sealing requirements are quite high.
What are the precautions for using R407C refrigerant during use?
R407C refrigeration equipment needs to be used with caution.
The first factor is its safety characteristics. R407C is flammable and has low flammability. However, in case of open fire, high temperature, etc., there is also a risk of fire and explosion. Therefore, in the place of use, it is necessary to prohibit fire and ensure good safety to prevent flammability.
Furthermore, the force characteristics of R407C should not be ignored. Its operating force and other common refrigeration equipment are affected. For safety, safety and repair, the tools and equipment used need to match their force characteristics, so that it is easy to cause leakage and failure.
In addition, the slippage of R407C also needs to be noted. Due to its mixed refrigeration system, there is a slip in the phase, which may affect the performance and efficiency of the refrigeration system. Therefore, this factor must be taken into account in order to achieve the best refrigeration effect.
In addition, when using R407C, it is necessary to pay attention to the compatibility of its lubricating oil. Use the matching lubricating oil to ensure that the lubricating oil and other components have a good slip and avoid grinding and failure due to poor slip. And in the case of repair and replacement parts, it is also necessary to pay attention to the inspection of lubricating oil.
Of course, the safety, force, slip and lubricating oil compatibility of the R407C refrigeration system need to be properly taken care of in order to ensure the safe and efficient operation of the refrigeration system.